This section lists the settings found in HID access control unit
Properties tab, in the Access control task.
This tab lets you update the connection parameters after the HID unit has been discovered,
such as the logon credentials, and the usage of certain specific inputs.
Connection settings
This section shows the connection parameters for
the Access Manager to communicate with the unit. These settings are initialized when the
HID unit is added to your system. Do not change these settings unless you changed them on
the unit through the unit’s web page or using the HID Discovery GUI after the unit was
enrolled, or one or our representatives instructs you to do so.Username and password:
Username and password used to log on to the HID unit.
Use translated host address:
Select this option when there is a NAT router between the unit and its Access Manager.
The NAT router’s IP address that is visible from the unit would be set here.
Static IP:
Select this option and configure the IP address, Gateway and Subnet mask manually if
the HID unit uses a fixed IP address (recommended).
Use DHCP:
Select this option if the HID unit will be assigned its IP configuration by a DHCP
server. When using the DHCP option, the DHCP server must be configured to always assign
the same IP address to the unit.
General settings
This section displays the general settings of the HID
unit.Server mode:
This option is always greyed out because HID units do not support server
mode.
Secure mode:
Enabling secure mode disables the insecure protocols
FTP and Telnet. It also makes the connection between the Access Manager and HID units
less susceptible to network impairments. This option is only available if the HID
unit meets the firmware requirement for secure mode.
Monitor AC Fail :
Select this option if the AC fail input is being used to monitor AC failures or
for some other general purpose.
Monitor battery fail :
Select this option if the Battery fail input is being used to monitor the
backup battery or for some other general purpose.
Reader supervision:
Select this option to enable reader supervision (ability to detect reader
disconnection or power loss in Security
Desk and Config
Tool). For this feature to
work, all readers connected to this HID unit must be configured for supervision. You
must also enable the supervision mode on each physical reader by presenting the HID
configuration card.
Timeout:
(Only if Reader supervision is selected) Timeout used to detect that the reader
is offline. We recommend that you
set the timeout value to be at least three times the cycle time of the I'm
alive signal (default=10 seconds) configured on the reader.