After generating a report, the results of your query are
listed in the report pane. This section lists the columns available for the relevant
reporting task.
Unit:
Name of the unit.
Unit type:
Type of unit (Access control, Intrusion
detection, LPR, or Video).
Product
type:
Model of the unit.
Role:
Role that manages the unit.
Firmware
version:
Firmware version installed on the
unit that generated the event.
Security protocol:
The security protocol used by the access manager (TLS,
Wiegand).
Upgrade status:
Status of the firmware upgrade (None, Scheduled, Started, Completed, or Failed).
Proposed
firmware version:
The recommended version
required for the upgrade. This column is blank for federated
units.
Authentication
scheme:
Indicates the type of
authentication being used by the camera unit, such as basic, digest,
anonymous, or third party. If the unit suddenly requests to connect
using a less secure authentication scheme, the Archiver rejects communication and the camera goes offline. For example, the Archiver expects the
camera to be using digest authentication, but the camera tries to connect using basic authentication. The connection is rejected and the
camera goes offline.
Proposed
firmware description:
The description of the
required upgrade. This column is blank for federated units.Up to date:
No firmware upgrade is necessary.
Optional:
The firmware upgrade is not urgent.
Recommended:
The firmware upgrade is recommended.
Security vulnerability:
The firmware upgrade fixes a security vulnerability issue and is
highly recommended.
NOTE: This information is only
available if Genetec™
Update Service is running.
IP address:
IP address of the unit or computer that
generated the event.
Password:
Strength of the password on the unit. When
you hover over the password strength value, a tooltip indicates if the
manufacturer default password is being used. "Unknown" is shown for
federated units.
State:
State of the unit (Online, Offline, Warning).
Time zone:
Time zone of the unit.
Platform version:
Current platform (cumulative security rollup) version installed on the
unit.
Manufacturer:
Manufacturer of the unit.
Next upgrade:
The date for the next upgrade based on the units' Delay upgrade until setting.
Physical
address:
The MAC address of the equipment's
network interface.
Proposed platform description:
The description of the required upgrade. This column is blank for
federated units.Up to date:
No platform upgrade is necessary.
Optional:
The platform upgrade is not urgent.
Recommended:
The platform upgrade is recommended.
Security vulnerability:
The platform upgrade fixes a security vulnerability issue and is
highly recommended.
NOTE: This information is only available if Genetec™
Update Service is
running.
Proposed platform version:
The recommended version required for the upgrade. This column is blank
for federated units.
Reason for upgrade failure:
Reason that the firmware upgrade failed (for example, Unit offline, or Firmware upgrade path not respected).
Secure mode:
(HID units only) Indicates whether secure mode enabled or
disabled.
User:
The user name used to connect
to the unit.
Custom
fields:
The predefined custom fields for the
entity. The columns only appear if custom fields are defined for the
entity, and if the custom fields were made visible to you when they were
created or last configured.