This section describes the supported HID access control unit configurations in Security Center.
Input | When used as | Required configuration |
---|---|---|
Request-to-Exit | Request-to-Exit input signal. |
|
General purpose input (for zone monitoring for example) |
|
|
Door monitor | Door position sensor input (door open or door closed) |
|
A door with a reader assigned to a V2000, V100, or an Edge device, must have all inputs (for example door contact, REX) and outputs (for example door lock) associated to that same device. Inputs and outputs must not be distributed across several devices.
It is not recommended to configure a door with two door sensors (or door contacts) without physically wiring the sensors in series. In the Security Center, only a single door sensor should be configured per door.