For your safety and for getting the best performance out of your equipment, follow the
recommended mounting and wiring instructions.
Mounting recommendations
- The controllers and interface modules must always be mounted in a secure area.
- Mount using the four mounting screws (provided) or other appropriate fasteners. Place
the fasteners in the corner holes of the base.
- The VertX devices can be stacked with or without the cover. Do not remove the plastic
base. Make sure you position the VertX devices in such a way as to provide room for
wiring, air-flow and cable runs.
Wiring recommendations
CAUTION: VertX controllers and interface modules are sensitive to Electrostatic
Discharges (ESD). Exercise precautions while handling the circuit board assembly by using
proper grounding straps at all times.
Network recommendations
- It is recommended to set a static IP address on the HID controller. The discovery
process is different for controllers that have a DHCP-assigned IP address. Discovery for
DCHP address through multiple VLAN is not supported. If the Access Manager is on a
different VLAN than the HID controller, the controller's IP address cannot be assigned by
DCHP.
- It is recommended to isolate the controller on the network from broadcast traffic or
unhandled multicast.
- The maximum number of character for the controller name should be 15, without spaces and
special characters.
- All HID controllers have the same factory-assigned IP address 169.254.242.121. You can
always log on to an HID unit from your computer using a network cable. The default logon
username and password for Legacy units are
root/pass
. The default logon
username for EVO units is admin
and the password is blank, unless it was
already set.